Previous Page

nihilist@mainpc - 2024-04-06

Electrical Failover (basic UPS setup)

Threat Model:

What if an adversary tells your electricity provider to temporarily power off your electricity to check if it manages to shut down a particular hidden service ? How do you ensure that your hidden service running at home remains accessible even without the main electrical input ?

In this tutorial we'll look at the most fundamental part of both Disaster Recovery Planning and Business Continuity for home servers. We'll look at how to deal with power outages.

For the Electrical Outages, we'll setup a UPS in between our homeserver and the main electrical input, so that in case of a power outage the home server can keep running for a while before finally shutting down. The UPS will then send a message to the Network UPS Tools suite to tell the server to shutdown when the batteries run low.

Electrical Outages - UPS setup

Before buying a UPS, you need to know how much your home server can draw power (in watts), to make it simple just look at your power supply in your Homeserver. Mine is a RM 750x:

and as explained in the technical specs, it can draw up to 750 Watts of power:

So you need a UPS that can generate at least 750 Watts of power, such as the APC Back-UPS 1600VA:

For my usecase, i picked that one because it can power my homeserver with the 900Watts it can output. Perfect for my server that can draw 750Watts.

First make sure your homeserver's plugged onto the UPS which is plugged onto the main electrical source. Then power on the homeserver, and after it booted, connect the serial to usb cable from the UPS to the homeserver, and you'll see it appear like so:


[ Wonderland ] [ /dev/pts/3 ] [~]
→ lsusb

[...]

Bus 003 Device 003: ID 051d:0002 American Power Conversion Uninterruptible Power Supply

[...]
	

Then, let's install network ups tools (nut) and make it scan for any ups connected via UPS like ours:


[ Wonderland ] [ /dev/pts/3 ] [~]
→ apt update -y ; apt install nut nut-client nut-server -y

[ Wonderland ] [ /dev/pts/3 ] [~]
→ sudo nut-scanner -U
Scanning USB bus.
[nutdev1]
        driver = "usbhid-ups"
        port = "auto"
        vendorid = "051D"
        productid = "0002"
        product = "Back-UPS BX1600MI FW:378600G -302202G"
        serial = "DWAADWAWDWA"
        vendor = "American Power Conversion"
        bus = "003"
	


[ Wonderland ] [ /dev/pts/3 ] [~]
→ cat /etc/nut/upsmon.conf
RUN_AS_USER root
MONITOR apc-ups@localhost 1 admin secret master

MINSUPPLIES 1
SHUTDOWNCMD "/sbin/shutdown -h +0"
POLLFREQ 5
POLLFREQALERT 5
HOSTSYNC 15
DEADTIME 15
POWERDOWNFLAG /etc/killpower
RBWARNTIME 43200
NOCOMMWARNTIME 300
FINALDELAY 5

[ Wonderland ] [ /dev/pts/3 ] [~]
→ cat /etc/nut/upsd.conf
LISTEN 0.0.0.0 3493

[ Wonderland ] [ /dev/pts/3 ] [~]
→ cat /etc/nut/nut.conf

MODE=netserver


[ Wonderland ] [ /dev/pts/3 ] [~]
→ cat /etc/nut/upsd.users
[monuser]
        password = secret
        admin master
	


[ Wonderland ] [ /dev/pts/3 ] [~]
→ systemctl status nut-server nut-client nut-monitor
● nut-server.service - Network UPS Tools - power devices information server
     Loaded: loaded (/lib/systemd/system/nut-server.service; enabled; preset: enabled)
     Active: active (running) since Sat 2024-04-06 17:23:47 CEST; 5s ago
   Main PID: 707274 (upsd)
      Tasks: 1 (limit: 76930)
     Memory: 620.0K
        CPU: 2ms
     CGroup: /system.slice/nut-server.service
             └─707274 /lib/nut/upsd -F

Apr 06 17:23:47 wonderland systemd[1]: Started nut-server.service - Network UPS Tools - power devices information server.
Apr 06 17:23:47 wonderland nut-server[707274]: fopen /run/nut/upsd.pid: No such file or directory
Apr 06 17:23:47 wonderland nut-server[707274]: Could not find PID file '/run/nut/upsd.pid' to see if previous upsd instance is already running!
Apr 06 17:23:47 wonderland nut-server[707274]: listening on 0.0.0.0 port 3493
Apr 06 17:23:47 wonderland upsd[707274]: listening on 0.0.0.0 port 3493
Apr 06 17:23:47 wonderland upsd[707274]: Connected to UPS [apc-ups]: usbhid-ups-apc-ups
Apr 06 17:23:47 wonderland nut-server[707274]: Connected to UPS [apc-ups]: usbhid-ups-apc-ups
Apr 06 17:23:47 wonderland nut-server[707274]: Running as foreground process, not saving a PID file
Apr 06 17:23:47 wonderland upsd[707274]: Running as foreground process, not saving a PID file

● nut-monitor.service - Network UPS Tools - power device monitor and shutdown controller
     Loaded: loaded (/lib/systemd/system/nut-monitor.service; enabled; preset: enabled)
     Active: active (running) since Sat 2024-04-06 17:23:47 CEST; 5s ago
   Main PID: 707276 (upsmon)
      Tasks: 2 (limit: 76930)
     Memory: 836.0K
        CPU: 2ms
     CGroup: /system.slice/nut-monitor.service
             ├─707276 /lib/nut/upsmon -F
             └─707277 /lib/nut/upsmon -F

Apr 06 17:23:47 wonderland systemd[1]: Started nut-monitor.service - Network UPS Tools - power device monitor and shutdown controller.
Apr 06 17:23:47 wonderland nut-monitor[707276]: fopen /run/nut/upsmon.pid: No such file or directory
Apr 06 17:23:47 wonderland nut-monitor[707276]: Could not find PID file to see if previous upsmon instance is already running!
Apr 06 17:23:47 wonderland nut-monitor[707276]: UPS: apc-ups@localhost (primary) (power value 1)
Apr 06 17:23:47 wonderland nut-monitor[707276]: Using power down flag file /etc/killpower
Apr 06 17:23:47 wonderland nut-monitor[707277]: Init SSL without certificate database
Apr 06 17:23:47 wonderland nut-monitor[707277]: Login on UPS [apc-ups@localhost] failed - got [ERR ACCESS-DENIED]

● nut-monitor.service - Network UPS Tools - power device monitor and shutdown controller
     Loaded: loaded (/lib/systemd/system/nut-monitor.service; enabled; preset: enabled)
     Active: active (running) since Sat 2024-04-06 17:23:47 CEST; 5s ago
   Main PID: 707276 (upsmon)
      Tasks: 2 (limit: 76930)
     Memory: 836.0K
        CPU: 2ms
     CGroup: /system.slice/nut-monitor.service
             ├─707276 /lib/nut/upsmon -F
             └─707277 /lib/nut/upsmon -F

Apr 06 17:23:47 wonderland systemd[1]: Started nut-monitor.service - Network UPS Tools - power device monitor and shutdown controller.
Apr 06 17:23:47 wonderland nut-monitor[707276]: fopen /run/nut/upsmon.pid: No such file or directory
Apr 06 17:23:47 wonderland nut-monitor[707276]: Could not find PID file to see if previous upsmon instance is already running!
Apr 06 17:23:47 wonderland nut-monitor[707276]: UPS: apc-ups@localhost (primary) (power value 1)
Apr 06 17:23:47 wonderland nut-monitor[707276]: Using power down flag file /etc/killpower
Apr 06 17:23:47 wonderland nut-monitor[707277]: Init SSL without certificate database
Apr 06 17:23:47 wonderland nut-monitor[707277]: Login on UPS [apc-ups@localhost] failed - got [ERR ACCESS-DENIED]

We can check if the server can get all the


[ Wonderland ] [ /dev/pts/3 ] [~]
→ upsc apc-ups@localhost
Init SSL without certificate database
battery.charge: 100
battery.charge.low: 10
battery.mfr.date: 2001/01/01
battery.runtime: 3167
battery.runtime.low: 120
battery.type: PbAc
battery.voltage: 27.2
battery.voltage.nominal: 24.0
device.mfr: American Power Conversion
device.model: Back-UPS BX1600MI
device.serial: DDWAWADWADADW
device.type: ups
driver.name: usbhid-ups
driver.parameter.pollfreq: 30
driver.parameter.pollinterval: 1
driver.parameter.port: auto
driver.parameter.productid: 0002
driver.parameter.serial: DWDADWAWDDWAADWDAW
driver.parameter.synchronous: auto
driver.parameter.vendorid: 051D
driver.version: 2.8.0
driver.version.data: APC HID 0.98
driver.version.internal: 0.47
driver.version.usb: libusb-1.0.26 (API: 0x1000109)
input.sensitivity: medium
input.transfer.high: 295
input.transfer.low: 145
input.voltage: 234.0
input.voltage.nominal: 230
ups.beeper.status: enabled
ups.delay.shutdown: 20
ups.firmware: 378600G -302202G
ups.load: 10
ups.mfr: American Power Conversion
ups.mfr.date: 2022/02/08
ups.model: Back-UPS BX1600MI
ups.productid: 0002
ups.realpower.nominal: 900
ups.serial: DAWDWDAWADWADWDAWAD
ups.status: OL
ups.test.result: Done and passed
ups.timer.reboot: 0
ups.timer.shutdown: -1
ups.vendorid: 051d

Now that the UPS is detected, we can install an interface for the nut service:


[ Wonderland ] [ /dev/pts/3 ] [~]
→ apt install nut-cgi -y
	
[ Wonderland ] [ /dev/pts/3 ] [~]
→ vim /etc/nut/hosts.conf

[ Wonderland ] [ /dev/pts/3 ] [~]
→ cat /etc/nut/hosts.conf

MONITOR apc-ups@localhost "APC UPS - 1600VA"

[ Wonderland ] [ /dev/pts/3 ] [~]
→ cat /etc/nut/upsset.conf
I_HAVE_SECURED_MY_CGI_DIRECTORY

[ Wonderland ] [ /dev/pts/3 ] [~]
→ apt install apache2 -y 

[ Wonderland ] [ /dev/pts/3 ] [~]
→ a2enmod cgi
Your MPM seems to be threaded. Selecting cgid instead of cgi.
Enabling module cgid.
To activate the new configuration, you need to run:
  systemctl restart apache2

[ Wonderland ] [ /dev/pts/3 ] [~]
→ systemctl restart apache2

And now we can browse it from the web on port 80: the url is: http://192.168.0.100/cgi-bin/nut/upsstats.cgi?host=apc-ups@localhost&treemode

we can see the following graph to know the Battery Charge, Voltage, Input and Load:

And for more details you can see the data tree:

Now let's test if it works by unplugging the main electrical source:

First thing you'll notice is the UPS starting to do a loud beep every 3 seconds, but you can see it in action from the web interface:

Here as you can see the UPS is working on battery, and slowly the charge is being drained from 100% (now at 97% after 5 minutes) Of course it's being drained slowly due to being on a low load (18% currently), meaning it could last another 20 minutes of electrical outage easily.

Nihilism

Until there is Nothing left.

About nihilist

Donate XMR: 8AUYjhQeG3D5aodJDtqG499N5jXXM71gYKD8LgSsFB9BUV1o7muLv3DXHoydRTK4SZaaUBq4EAUqpZHLrX2VZLH71Jrd9k8


Contact: nihilist@nihilism.network (PGP)